Table34.SubmenusundertheHardwareHealthConguration(continued)
ItemOptionDescription
H/WHealthFunctionDisabled[Enabled]
Enableordisablethehardware
monitorfunction.
AutoFANControlDisabled[Enabled]
IfthisoptionissettoDisabled,the
fanrunsatthefullspeed;ifthisoption
issettoEnabled,thefanspeedis
controlledbythesystemtemperature.
PWMMinimalDutyCycle[60%DutyCycle]45%DutyCycle30%
DutyCycle
SelectthePWMMinimalDutyCycle
forthefan:60%-100%,45%-100%,
or30%-100%.
FanFailureLEDIndication
Disabled[Enabled]
Enableordisablethefanalarm
function.Ifthisoptionissetto
Enabled,amessageaboutfanfailure
willbedisplayedonthePOSTscreen
whentherotationalspeedofeachfan
islessthan800rpm.
HardwareHealthEventMonitoring
ReadOnly
Thesensordatainthisoptionisfor
readonly.Thedetecteddataincludes
thetemperatureandsystemfan
rotationalspeed.
Note:Thesettingsin[]arethedefaultsettingsintheSetupUtilityprogram.
Table35.SubmenusundertheIPMI2.0Conguration
ItemSub-itemOptionDescription
ViewBMCSystemEvent
Log
Viewthesystemeventlog.
ClearBMCSystemEvent
Log
Deletethesystemevent
log.
SetLANCongurationSettheIPaddresssource,
IPaddress,subnetmask,
andgatewayaddress.
SetPEFCongurationPEFSUPPORTDisabled[Enabled]
EnableordisablethePEF
support.
BMCWatchDogTimer
Action
[Disabled]Reset
SystemPowerDownPower
Cycle
DisableorenabletheOS
baseddongle.Ifenabled,
wheneveranyproblems
arisingfromtheoperation
system,suchasthe
systemhalted,thesystem
managementfeaturewill
takeactionsofReset
System,PowerDown,or
PowerCycleattheprompt
ofthedongleTimer.
BMCAlertLEDandBeep[Off]OnTurnonorturnofftheBMC
alertLEDandbeep.
FWkey
[0000000]
Note:Thesettingsin[]arethedefaultsettingsintheSetupUtilityprogram.
114ThinkServerRD230HardwareMaintenanceManual