Figure44.InstallingtheRAIDcontrollerintothePCIcardslot1ontherisercardassembly
Note:TherearethreePCIcardslotsontherisercardassemblyasshownintheillustration.ThePCI
cardslot12isforRAIDcardsonly.FormoreinformationaboutthePCIcardslots,see“Installinga
PCIcard”onpage55.
8.InstalltherisercardwiththeRAIDcontrollerintoanappropriatePCIcardslotonthesystemboard.
9.Connecttheotherendofthetwo400mm(15.75inches)miniSASsignalcablestothebackplaneof
yourserver.
Figure45.MiniSASsignalconnectorsonthebackplane
a.ForoneminiSASsignalcable,connecttheotherendtotheminiSASsignalconnector2onthe
backplane.
b.FortheotherSASsignalcable,connecttheotherendtotheminiSASsignalconnector1onthe
backplane.
Whattodonext:
•Toworkwithanotherpieceofhardware,gototheappropriatesection.
•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage90
.