7.PositiontheRAIDcontrollerneartherisercardassembly.EnsurethattheleftedgeoftheRAIDcontroller
isinsertedintothenotchoftheRAIDcardretentionbracket1,andthenrmlyinserttheRAIDcontroller
straightdownintothePCIcardslot12untilitissecurelyseated.Theninstallthescrew3tosecurethe
RAIDcontroller.
Figure49.InstallingtheRAIDcontrollerintothePCIcardslot1ontherisercardassembly
Note:TherearethreePCIcardslotsontherisercardassemblyasshownintheillustration.ThePCI
cardslot12isforRAIDcardsonly.FormoreinformationaboutthePCIcardslots,see“Installinga
PCIcard”onpage55.
8.InstalltherisercardwiththeRAIDcontrollerintoanappropriatePCIcardslotonthesystemboard.
9.Connecttheotherendofthetwo400mm(15.75inches)miniSASsignalcablestothebackplaneof
yourserver.
Figure50.MiniSASsignalcableconnectorsonthebackplane
a.ForoneminiSASsignalcable,connecttheotherendtotheminiSASsignalcableconnector2on
thebackplane.
b.FortheotherminiSASsignalcable,connecttheotherendtotheminiSASsignalcableconnector
1onthebackplane.
72ThinkServerRD240HardwareMaintenanceManual