163
Description:
NetFn
0x3c
Command
0x29
Request Data:
Byte
Data field
NONE
NONE
Response Data:
Byte
Data field
1
Completion Code
2.34 Sync RTC Time (UTC) to BMC
This command is to sync rtc time (utc) to bmc.
Linux command:
$ ipmitool raw 0x3c 0x30
Description:
NetFn
0x3c
Command
0x30
Request Data:
Byte
Data field
NONE
NONE
Response Data:
Byte
Data field
1
Completion Code
2.35 Get SEP Control Register
This is the command to get psoc control register.
Linux command:
$ ipmitool raw 0x3c 0x33