board assembly (see “Remove the ID label plate” on page 55 and “Install the ID label plate” on
page 56).
Note: If your compute node has an RFID tag, it is already attached to the ID label plate.
Step 19. The replacement system-board assembly comes with a Repair Identification (RID) tag. Using a fine
tip indelible ink pen, transfer the machine type and serial number from the defective system-board
assembly to the label on the Repair Identification tag; then, place the tag in the recessed area 1 on
the bottom of replacement system-board assembly.
Figure 67. Repair Identification (RID) tag
After you transfer components to the replacement system-board assembly, complete the following steps:
1. Install the compute node in the chassis (see “Install the compute node in the chassis” on page 25).
2. If an Attention label is on the replacement system-board assembly front panel above the power button,
read it; then, remove the label and discard it before turning on the compute node.
3. Use the CMM Web Interface to restore the IP address of the compute node XClarity controller. See
Starting the web interface in the "Flex System Chassis Management Module: User's Guide" at http://
Chapter 3. Hardware replacement procedures 85