EasyManua.ls Logo

Lenovo ThinkSystem ST550 - Install a Front Fan

Lenovo ThinkSystem ST550
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 1. If there is a power-supply-bay filler installed, remove it.
Important: To ensure proper cooling during normal server operation, both of the power supply
bays must be occupied. This means that each bay must have a power supply installed; or one has
a power supply installed and the other has a power-supply filler installed.
Figure 57. Hot-swap power supply filler removal
Step 2. Slide the new hot-swap power supply into the bay until it snaps into position.
Figure 58. Hot-swap power supply installation
Install a front fan
Use this information to install a front fan.
“Read the
installation
Guidelines” on
page 58
“Power off
the server for
this task” on
page 109
“ATTENTION:
Static Sensitive Device
Ground package before opening”
on page 59
Chapter 3. Server hardware setup 95

Table of Contents