Read “Installation guidelines” on page 58 to ensure that you work safely.
Power off the server and disconnect all power cords for this task.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
If the server is in a rack, remove it from the rack.
If foot stands are installed on the server, rotate them inwards and lay the server on its side for easier
operation.
Locate the flash power module slot on the air baffle.
Figure 42. Flash power module slot location
Table 40. Flash power module slot location on air baffle
1 Flash power module slot 1 3 Flash power module slot 3
2 Flash power module slot 2 4 Flash power module slot 4
Watch the procedure. A video of the installation and removal process is available:
YouTube:
https://youtube.com/playlist?list=PLYV5R7hVcs-DoEcxrm2zKNpaKOdZ3f8Qc
Youku: https://list.youku.com/albumlist/show/id_59636516
Procedure
Step 1. Disconnect the cable of the flash power module from the RAID adapter.
Step 2. Remove the flash power module.