8100_ A Technical description
Lenze
67
Code leve l PRG Parameter level
Factory
Customer
<===>
settings settings
* C119 preselection:
Enter the des;red surveillance function with C119,
Survei Llance
then set the function using C120.
. - - - -- - -- --- --. -- -- . - -- - -- - -- --- -- - -- - -- --- -- - -- - -- --- --
-0- SH+ PRG ExternaLfault
-0-
---------------------------------------------------------
-1- SH+ PRG
PTCinput
--.------------------------
------------------------------------------------------.--
--------- ----_.-----
* C120 Surveillance
-0- SH+ PRGSurveillance not active
external
tunetion for
---------------------------------------------------------
fault
IC119J
-1-
SH+ PRGSurveillance active,
TRIP
-1-
---------------------------------------------------------
PTCinput
-2-
SH+ PRGSurveillance active, warning
-1-
* C125
LECOM1-Baudrate -0- SH+ PRG
9600 Baud -0-
---------------------------------------------------------
-I- SH+ PRG 4800 Baud
---------------------------------------------------------
-2-
SH + PRG 2400 Baud
---------------------------------------------------------
-3-
SH + PRG 1200 Baud
* C130 Enable
-0- SH+ PRG Tir (C012)/Tif (COB) active
-0-
additional
---------------------------------------------------------
Ti times
-1-
SH+ PRG Tir1ITif1 active
---------------------------------------------------------
-2- SH+ PRG Tir2/Tif2 active
---------------------------------------------------------
....
---------------------------------------------------------
-15
SH+ PRG
Tir15/Tif15 active
* CB1 Ra function -0- SH+ PRG
Ra function generator is enabled
-0-
generator stop
----------------------------------------.----------------
(set-value 1)
-1-
SH+ PRG
R8n'4'function generator is stopped
* CB2 Ra function -0-
SH + PRG
Inputsignal of ra function generator
-0-
generator input = 0
is set-value 1
(set-value 1)
---------------------------------------------------------
-1-
SH + PRG
Input of rarrp funct ion generator
is set to zero
* CB4
Rarrpfunct ion
-0- SH + PRG linear characteristic
-0-
generator
-----------------------------------------.---------------
characteristic -1-
SH + PRG
S-shaped characteristic
(set-value 1)
---------------------------------------------------------
Change is only possible when controller inhibited'
* C143 Threshold for
XXX
0,0_. .10,OHz
Threshold for fCH reduction to 1 kHz
0.0 Hz
fCH reduction
* C160 Display
-x-
Process step X active
-0-
process step
X =0 Process control not active/finished
* C161 Codes C161 to C168 contain the eight last faults
:
which were reset under C067. They can only be
: read via the LEC04interface
C168 (for LECOMnumers see C067)
* C172
Set-value input
-0-
SH + PRG
Set-value 1 (C046) is entered
-0-
relative to fdnax
---------------------------------------------------------
-1- SH + PRG
Set-value 1 (C046) is entered
absolute as frequency
---------------------------------------------------------
Change is only possible when controller inhibited!