Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23 69
11 Diagnostics
11.3 Diagnostic data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.3 Diagnostic data
• The I/O device sends an alarm message to the I/O controller to signalise the diagnostic data
below.
• Errors and warnings in the Inverter Drive 8400 motec are sent to the IO controller as extended
diagnostic messages.
• The diagnostic data can be displayed using the hexadecimal representation of the Siemens S7
engineering tool.
Error code of the Inverter Drive 8400 motec
• The error code can be found in bytes 29 ... 32 of the diagnostic message.
• In the logbook and in code C00165, the error number is shown in the following syntax in order
to facilitate the readability:
[error type].[error subject area no.].[error ID]
Example: error message "PROFINET: Data_Exchange status quit [0x01bc6531]
"
Bytes Meaning Value [hex]
1 ... 6 Diag. block header 0x0010 001C 0100
7 ... 8 Alarm type 0x0001 (diagnosis)
9 ... 12 API 0x0000 0000
13, 14 Slot number 0x0001 / 0x0002
15, 16 Subslot number 0x0001
17 ... 20 Module ID ID according to module
21 ... 24 Submodule ID ID according to module
25, 26 Alarm specifier 0xB000
27, 28 User structure identifier 0x0001
29 ... 32 Error code of the Inverter Drive 8400 motec
Byte 32 Byte 31 Byte 30 Byte 29
0x01 0xbc 0x65 0x31
0 0 0 0 0 0 0 1 1 0 1 1 1 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 0 0 0 1
Response Instance ID Module ID Error ID