Function library
DFOUT (master frequency output)
12
305
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C0540] X8 Signal out 2
Function of the digital frequency
output signals on X8 (DFOUT)
304
103
0 DFOUT in [%]
1 DFOUT in [rpm]
2 Encoder simulation + zero pulse ®
DFOUT
C0545 PH offset 0
Phase offset
304
0 {1 inc} 65535 1 revolution = 65535 increments
C0547 DIS: AN−IN
Analog signal on the input of the
DFOUT block
Read only
304
−199.99 {0.00 %} 199.99
C0549 DIS: DF−IN
Speed on the input of the DFOUT
block
Only display
304
−32767 {1 rpm} 32767
C6430 DFOUT
Display of the analog output
signal DFOut−Out in the DFOUT
function block
304
−32768 {1} 32767
[C6431] DFOUT 1000
Selection of the analog output
signal DFOut−Out for the DFOUT
function block
304
FIXED 0 % (not assigned)
For possible signals see "selection list − analog
signals"
437