Appendix
Code table
13
365
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0022 Imax current à
I
max
limit
0 {0.01 A} à Device−dependent list
Max. current can be gathered
from the technical data.
C0023 Imax fld.weak 0
Maximum field weakening
current for synchronous
machines
0 {1 %} 100
C0026 Offset for relative analog signals
(AIN)
266
309
1 FCODE(offset) 0,0 −199,99 {0.01 %} 199,99 FCODE_nC26_1_a
2 FCODE(offset) 0,0 FCODE_nC26_2_a
C0027 Gain for relative analog signals
(AIN)
266
309
1 FCODE(gain) 100,0 −199,99 {0.01 %} 199,99 FCODE_nC27_1_a
2 FCODE(gain) 100,0 FCODE_nC27_2_a
C0030 DFOUT const 3
Constant for the digital
frequency signal DFOUT_nOut_v
on X8 in increments per
revolution
304
106
113
0 256 incr./rev
1 512 incr./rev
2 1024 incr./rev
3 2048 incr./rev
4 4096 incr./rev
5 8192 incr./rev
6 16384 incr./rev
C0032 FCODE
Gearbox
1
Freely configurable code for
gearbox factor ?
(FCODE_nC32_a)
309
−32767 {1} 32767
C0034 Mst current 0
Master voltage/master current
on analog input (AIN1_nIn_a)
266
0 −10 ... + 10 V Master voltage
1 +4 ... +20 mA
Master current
2 −20 ... +20 mA
C0037 Set−value rpm 0
Setpoint selection in rpm
(FCODE_nC37_a)
309
−16000 {1 rpm} 16000
C0039 15 fixed setpoints
Can be retrieved via digital
signals SPEED−NSET.Jogx.
326
1 JOG
SET−VALUE
0.00
−199.99 {0.01 %} 199.99 Relating to n
max
(C0011)
2 JOG
SET−VALUE
0.00
... JOG
SET−VALUE
0.00
14 JOG
SET−VALUE
0.00
15 JOG
SET−VALUE
0.00