Appendix
Code table
13
366
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0040 Ctrl enable 1
Controller enable / controller
inhibit (CINH)
l Writing: Controls the
controller inhibit
l Reading: Reads the status of
the controller inhibit
0 Controller inhibited
1 Controller enabled
C0042 DIS: QSP
Quick stop status (QSP)
Only display
297
144
0 QSP not active
1 QSP active
C0043 Trip reset 0
Reset active fault message
(TRIP−RESET)
246
0 Reset fault message (TRIP−RESET) / no
fault
1 Active fault message
C0050 MCTRL−NSET2
Speed setpoint on speed
controller input
(MCTRL_nNSetIn_a)
Read only
−100,00 {0.01 %} 100.00
C0051 MCTRL−NACT
Actual speed (MCTRL_nNAct_a)
Read only
−30000 {1 rpm} 30000
C0052 MCTRL Umot
Actual motor voltage
Read only
0 {1 V} 800
C0053 UG−VOLTAGE
DC−bus voltage
Read only
0 {1 V} 900
C0054 Imot
Actual motor current
Read only
0,0 {0.1 A} 500,0
C0055 Phase current Motor phase current
Read only
1 iu
0,0 {0.1 A} 500,0
Actual current in U phase
2 iv Actual current in V phase
3 iw Actual current in W phase
4 Io Actual theoretical star−point
current
C0056 MCTRL−MSET2
Torque setpoint on speed
controller output
(MCTRL_nMSetIn_a)
Read only
−100 {1 %} 100
C0057 Max Torque
Maximum possible torque of the
drive configuration
Dependent on C0022, C0081,
C0087, C0088
Read only
0,0 {0.1 Nm} 500,0