Appendix
Code table
13
368
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0070 Vp speedCTRL 3.0
Proportional gain of speed
controller (V
pn
)
154
0.00 { 0.01} 127.99
C0071 Tn speedCTRL 24.0
Reset time − speed controller
(T
nn
)
154
1.0 {0.5 ms} 6000.0
C0072 Td speedCTRL 0.0
Derivative gain of speed
controller (T
dn
)
154
0.0 {0.1 ms} 32.0
C0074 Dynamics 0
Pilot control of the current
controller for higher dynamics
149
0 Normal
1 Enhanced
C0075 Vp currCTRL 20.0
Proportional gain of current
controller (V
pi
)
The upper limit is
device−dependent.
149
0.00 {0.01 W} 381.80 ECSxS/P/M/A004
190.90 ECSxS/P/M/A008
95.46 ECSxS/P/M/A016
47.72 ECSxS/P/M/A032
31.82 ECSxS/P/M/A048
23.86 ECSxS/P/M/A064
C0076 Tn currCTRL 5.0
Reset time of current controller
(T
ni
)
149
0.01 {0.01 ms} 200.00
C0077 Vp fieldCTRL 5.0
Field controller gain (V
pF
)
157
0.00 {0.01} 63.99
C0078 Tn fieldCTRL 20.0
Field controller reset time (T
nF
)
157
1.0 {0.5 ms} 6000.0
C0079 DIS:Lh
Mutual inductance of the
asynchronous motor
Read only
0.0 {0.1 mH} 3276.7
[C0080] Res pole no. 1
Number of pole pairs of resolver
1 {1} 10
[C0081] Mot power 3.20
Rated motor power according to
nameplate
0.01 {0.01 kW} 500.00
[C0082] DIS:Rr
Rotor resistance of the
asynchronous motor
Read only
0.000 {0.001 W} 32.767
C0083 DIS:Tr
Rotor time constant of the
asynchronous motor
Read only
0.00 {0.01 ms} 327.67