EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C0084] Mot Rs 1.10
Stator resistance of the motor
The upper limit is
device−dependent.
0.00 {0.01 W} 95.44 ECSxS/P/M/A004
47.72 ECSxS/P/M/A008
23.86 ECSxS/P/M/A016
11.93 ECSxS/P/M/A032
7.95 ECSxS/P/M/A048
5.96 ECSxS/P/M/A064
[C0085] Mot Ls 5.30
Leakage inductance of the motor
0.00 {0.01 mH} 200.00
[C0087] Mot speed 3700
Rated motor speed
300 {1 rpm} 16000
[C0088] Mot current 7.0
Rated motor current
0.5 {0.1 A} 500.0
[C0089] Mot
frequency
185
Rated motor frequency
10 {1 Hz} 1000
[C0090] Mot voltage 325
Rated motor voltage
50 {1 V} 500
[C0091] Mot cos phi 1.0
cos j of the asynchronous motor
0.50 {0.01} 1.00
C0092 DIS:Isdeff
Magnetising current of the
asynchronous motor
Read only
0.00 {0.01 A} 327,67
C0093 Drive ident
Device identification of the ECS
axis module
Read only
0 Defective power section
1 No power section recognised
4 ECSxS/P/M/A004C4
8 ECSxS/P/M/A008C4
16 ECSxS/P/M/A016C4
32 ECSxS/P/M/A032C4
48 ECSxS/P/M/A048C4
64 ECSxS/P/M/A064C4
65 ECSxS/P/M/A064C2
C0094 Password 0
Keypad password
Parameter access protection for
the keypad
0 {1} 9999
When the password is activated,
only the codes of the user menu
(C0517) can be accessed. Further
possible selections: see C0096
0 = no password