Appendix
Code table
13
394
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0605 MONIT OH5 2
Fault response − monitoring of
temperature inside the
controller.
Temperature threshold can be
set under C0124.
205
0 TRIP
2 Warning
3 Off
C0606 MONIT OC8 2
Fault response − monitoring of
I
2
x t motor utilisation.
Threshold can be set under
C0120.
210
0 TRIP
2 Warning
3 Off
C0607 MONIT NMAX 0
Fault response − maximum speed
monitoring of the machine
0 TRIP
2 Warning
3 Off
C0608 ovr. Tx−Queue 2
Fault response − transmission
memory overflow of free CAN
objects
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP
C0745 Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
C0746 Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
1
...
24
C0747 Only the Lenze service is allowed
to make changes!
Oscilloscope − internal service
C0855 Digital process data input words
are indicated on the AIF interface
(AIF1_IN)
Hexadecimal value is bit−coded.
Read only
248
1 AIF1 IN bits 0000 {hex} FFFF Input word 2 (bit 0 ... 15)
2 AIF1 IN bits Input word 3 (bit 0 ... 15)