LERICA C310 - Troubleshooting Common Problems

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
109
EN
USER
Rev. 03 - 07/2015 - Cod. 1501151 - Instruction manual for vacuum chamber packaging machines
Mod. C254-C308-C312-C412-C420

Switchthemachineoffviatheon/offmainswitchanddisconnecttheplugfromthemains.
• Spraythesteelsurfacesofthemachinewithanalcohol-baseddisinfectant.Donotspraytheproducton
electricpartsorintheventilationslotsofthemachine.
• Letthedisinfectantsitforafewminutes.
• Wipewithaclothsoakedindrinkingwaterandthendrywellwithacleancloth.

  SOLUTION
 
-


• Vacuum pump or sealingtran-
sformeroverheating.
• Waitapproximately15or20minutesforthe
appliancetocool;attheendofthisperiodthe
vacuumchamberwillbedepressurisedand
theworkcyclecanberesumed.

  
   
  




• Applianceoverheating. • Switchofftheappliance andthen switchit
onagainafteranintervalofbetween15and
20 minutes.
• Safetycontrolcircuitfault. • Contactanauthorisedservicecentre.
 • MachineOff. • SwitchonthemachineusingtheON/OFF
mainswitch.
• Nopowersupply. • Insertthepluginasocket(checkthevolta-
ge!).
• Checkpowercabletomakesureitisintact.
• CheckfusePF1onthepowerboardtomake
suretheyareintactandinserted correctly
(contact a service centre).
• Machinedamage. • Contact a Service centre.

• Setvacuumvalueinsufcient • IncreasethevalueusingtheUPandDOWN
keys.
• Vacuum pump performancein-
sufcient.
• Checkoil.
• Checkpumpexhaustlter(contactaservice
centre).
• Covergasketworn. • Replacecovergasket.


• Pressure exerted on Plexiglas
coverduringappliancestartup
insufcient.
• Lowercoverwithbothhands,exertingmore
pressure.
• For appliance with gasoption:
gas function active.
• Deactivatethegasfunction.
• Pumpnotworking. • Contact a Service Centre.
 • Covergasketworn. • Changethegasket.
• Hinges out of alignment. • Adjust the cover hinge (contactaService
Centre).
• Gasspringdamaged. • Replacegasspring(contactaServiceCen-
tre).