Rev. 03 - 07/2015 - Cod. 1501151 - Instruction manual for vacuum chamber packaging machines
Mod. C254-C308-C312-C412-C420
Switchthemachineoffviatheon/offmainswitchanddisconnecttheplugfromthemains.
• Spraythesteelsurfacesofthemachinewithanalcohol-baseddisinfectant.Donotspraytheproducton
electricpartsorintheventilationslotsofthemachine.
• Letthedisinfectantsitforafewminutes.
• Wipewithaclothsoakedindrinkingwaterandthendrywellwithacleancloth.
SOLUTION
-
• Vacuum pump or sealingtran-
sformeroverheating.
• Waitapproximately15or20minutesforthe
appliancetocool;attheendofthisperiodthe
vacuumchamberwillbedepressurisedand
theworkcyclecanberesumed.
• Applianceoverheating. • Switchofftheappliance andthen switchit
onagainafteranintervalofbetween15and
20 minutes.
• Safetycontrolcircuitfault. • Contactanauthorisedservicecentre.
• MachineOff. • SwitchonthemachineusingtheON/OFF
mainswitch.
• Nopowersupply. • Insertthepluginasocket(checkthevolta-
ge!).
• Checkpowercabletomakesureitisintact.
• CheckfusePF1onthepowerboardtomake
suretheyareintactandinserted correctly
(contact a service centre).
• Machinedamage. • Contact a Service centre.
• Setvacuumvalueinsufcient • IncreasethevalueusingtheUPandDOWN
keys.
• Vacuum pump performancein-
sufcient.
• Checkoil.
• Checkpumpexhaustlter(contactaservice
centre).
• Covergasketworn. • Replacecovergasket.
• Pressure exerted on Plexiglas
coverduringappliancestartup
insufcient.
• Lowercoverwithbothhands,exertingmore
pressure.
• For appliance with gasoption:
gas function active.
• Deactivatethegasfunction.
• Pumpnotworking. • Contact a Service Centre.
• Covergasketworn. • Changethegasket.
• Hinges out of alignment. • Adjust the cover hinge (contactaService
Centre).
• Gasspringdamaged. • Replacegasspring(contactaServiceCen-
tre).