Powertrain
5
S023074 PA1
2020-05-12
75
Air Flow Restrictions
Do not obstruct air flow to the radiators. Refer to Cooling and air intakes,
page 19 for more
information.
Accessory Drive
WARNING
Do not install an alternator or pumps that need a mechanical drive from the
engine.
The engine only runs when it is necessary, to charge the battery or meet a sudden demand for
power. This makes it unsuitable to for the installation of belt driven pumps and alternators used
on vehicles powered by an internal combustion engine only.
The vehicle does not have an alternator, accessory drive belt or tensioner. Electrical power is
supplied by the batteries or generated by the Crank Integrated Starter Generator (CISG).
NOTE
For additional information or technical support contact Aftersales@LEVC.com.
Exhaust System
Exhaust system modifications
CAUTION
Changes to the exhaust system must be tested. Changes must comply with
requirements for back pressure, noise and emissions.
NOTE
For additional information or technical support contact Aftersales@LEVC.com.
If you modify the exhaust system:
Bends must have a radius of 2.5 x the diameter of the pipe.
45 degree and 90 degree welded joints in the exhaust pipe are not permitted.
Gas must flow from smaller to larger diameter pipes.
Exhaust Pipes and Supports
Do not install components within 30 mm of the exhaust system. Heat from the exhaust system
could damage components installed in the conversion.
Exhaust Heat Shields
CAUTION
Do not remove the heat shields. The heat shields are necessary to protect other
components from heat produced when the engine operates.