User Manual for BPS-i100
www.levitronix.com
PL-4036-00, Rev03, DCO# 21-057
Figure 22: Temperature curves for the IPD-100.2-50 driver @ 70°C liquid temperature
Note 1 Typical data for pumping with pump head LPP-200.7 and IPD-100.x drivers.
Figure 23: Temperature for cooling with water cooling module WCM-100.1 @ 90°C liquid temp.
Note 1 Typical data for pumping with pump head LPP-200.7 and IPD-100.x drivers.
77
97
117
137
157
177
0.0 1.0 2.0 3.0 4.0 5.0
25
35
45
55
65
75
85
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0
[°F]
[gallons/min]
[°C]
[liters/min]
Absolute Temperature Limit
Recommended Operational
Temperature Limit
5000 rpm
6000 rpm
7000 rpm
8000 rpm
9000 rpm
4000 rpm
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Ambient Temp.: 25°C
77
97
117
137
157
177
0.0 1.0 2.0 3.0 4.0 5.0
25
35
45
55
65
75
85
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0
[°F]
[gallons/min]
[°C]
[liters/min]
Absolute Temperature Limit
Recommended Operational Limit
5000 rpm
6000 rpm
7000 rpm
8000 rpm
9000 rpm
4000 rpm
Ambient Temp = 25°C
Liquid Temp. = 90°C
Specific gravity = 1g/cm
3
Viscosity = 0.7cP
Cooling with water cooling module WCM-100.1 and
cooling liquid flow = 0.5 l/min at 20°C temperature.