9 Appendix
9.1 Regulatory Status
9.1.1 CE Marking
We herewith declare that the Centrifugal Pump System Family BPS-i100, in its various configurations, is in
conformity with the below mentioned European Directives.
Machinery Directive 2006/42/EC:
The machinery directive essentially has been followed by a risk analysis, according mitigation actions and a
user manual for safe operation. For the design and testing the following standards are used as a guideline:
Pumps for Fluids: basic requirements are followed.
Procedure for hydrostatic pressure testing in fluid pumps: used for max. pressure testing of pump head.
Safety for machinery – principles for risk assessments: used for system risk analysis.
EMC Directive 2014/30/EC:
The following standards of the EMC directive are tested and confirmed at a certified laboratory:
Generic standards, Immunity for industrial environments
Generic standards, Emission standard for industrial environments
9.1.2 ATEX / IECEx Certification and Marking
Specific pump drivers with pump heads of the BPS-i100 pump system together with specific
accessories are in conformity with the requirements of the Directive 2014/34EU and the applicable
IEC standards. The following standards are tested and confirmed at a certified laboratory.
Explosive atmospheres - General requirements.
Explosive atmospheres - Equipment protection by increased safety “e”
Explosive atmospheres - Equipment protection by encapsulation “m”
Explosive atmospheres - Equipment dust ignition protection by enclosure “t”
Explos. Atmosph. - Non-electr. equipment for explosive atmosph. – Basic method and requirements
Explosive atmospheres - Non-electrical equipment for explosive atmospheres – Non electrical type of
protection constructional safety “c”, control of ignition source “b”, liquid immersion “k”
The Levitronix Ex pump drivers are marked clearly and in accordance to the ATEX Directive and
the relevant IECEx standards.
II 3G Ex ec h mc IIC T4 Gc
II 3D Ex h tc IIIC T90 °C Dc
Category 3GD (Zone 2 for Gas and Zone 22 for Dust)
Thermal classification of the driver is 120 °C (T4) (120 °C = 393 °F) for maximum full-load
operating temperature at a maximum liquid temperature of 70 °C / 158 °F.
9.1.3 Disposal of Equipment – WEEE Directive 2012/19/EU
Follow local legislation for disposal of equipment. In the European Union (EU) marked ( ) devices are governed by the
European WEEE Directive 2012/19/EU. Do not dispose with normal waste.