GA 05.139/1.02 - 06/99
Installation
16
M = 60,000 Nm
M = 60,000 Nm
Correct
Wrong
Fig. 13 Vacuum chamber fixed to the floor
125
°
70
°
30
°
ø
310
15
°
Fig. 14 Fixing the pump at the bottom
Boreholes M8,
15 mm deep