normal alarming. If the air filter is blocked, this
alarm indicator shall be on. At this time, always
check the metal and paper filter element for
blockage, and service or replace it in time.
d. The oil bath type air filter should not be over oiled.
The oiling depth should not exceed the oil level line
or the oil charge should not larger than 4l;
As a general rule, the oil bath type air filter should
maintained after being used for 200~250 hours.
10) Before the start-up, check whether there is any
personnel or obstructions in the vicinity of vehicle.
3.6.2 Engine start
1) Power operation
The main power switch is located outside the
battery box of frame side rail and key switch positions
are given in the table below.
△
! CAUTION: When the vehicle is running, do
not turn off the key switch. In other words, the key
switch shall be set and held at ON position (driving
position).
2) Start-up
Release the hand brake, and set the gearshift lever to