4. When the spring is released pull out the
bolt.
NOTE:
The bolt may be difficult to pull out,
because of pressure on the door actuator.
6. If the door is equipped with an automatic
door lock, unlock it with a triangular key
(automatic door lock is only available on
EasyLift 1100 V3 PLUS).
When the fault has been corrected, the door can be connected again following this instruction
in reverse order.
6.10.3 Emergency lighting/power failure
In the event of power failure or if the power supply to the lift’s controls is interrupted for some
reason, the system will automatically shift to back-up mode. This means that the system will
continue to operate because the lift will then be supplied by a back-up battery. The operating
panel will continue to be lit up. An acoustic alarm alerts the user that the lift is not in a ‘normal
operating situation’.
6.10.4 Electrical or mechanical faults/defects
In the event of (certain) mechanical or electrical faults, the lift will automatically enter into a
special “safety mode”, that only allows it to moved downward at low speed. It is not possible to
move upward, see section 11.2.