11. Operation
Under normal operating conditions the lift shall always be connected to 100-240V. It is very
important that the power is not disconnected or switched off, as long-standing power outage
(10-20 hours) may result in flat batteries and thus inoperability. Thus the lift cannot be used
until the batteries have been recharged. An audible alarm will sound if the power supply is
interrupted (see section 10.8).
11.1 Battery backup
In the event of 110-240V power failure or if the control unit is for some other reason not supplied
with power, the system will automatically switch to backup mode. This means the system will
continue to function as normal since it is being powered by the battery backup. Mains power
failure will be signaled by a beeping alarm sound; as soon as the mains is reconnected this alarm
will cease. The system is now running as normal.
If it is not possible to re-establish the mains supply immediately and you wish to cancel the
alarm, press the emergency stop button. (Note that in such a case the system will need to be
calibrated, see section 11.2).
IMPORTANT! If not connected to mains and the emergency button is not pressed,
the batteries will finally be drained. In the event of a long-standing power outage, the
emergency stop should be activated to ensure that the batteries are not completely
discharged.
IMPORTANT! If both the power supply has been disconnected and the emergency
stop activated at the same time, the system will automatically switch to “safety
mode” and will then need calibrating, see below.
11.2 Calibration following emergency stop/power failure
If the emergency stop has been activated and the power supply interrupted, or if the system
registers any other form of irregularity, the lift must be calibrated. The lift automatically enters
into a special “safety mode” that only allows it to move down at low speed until the lift reaches
the lower level.
IMPORTANT! If the lift does not operate as expected or stops again after a few
inches/centimetres, technical problems may have arisen and require a repair by
technical staff. Contact your dealer for further assistance.