4. The printed circuit containing the trans-
mitter is now visible and should be briefly
pressed at S4 in order to pair it with the
receiver (must be done within 2
minutes).
5. Test the system to ensure that the pairing has been done correctly; if not, repeat points 1-
4.
6. If several remote controls are to be paired with the receiver, repeat from step 2 above.
7. Replace the top cover
To reset a call station/call station pillar so that it is no longer paired with the lift, the following
points should be followed:
How to reset the transmitter:
1. Press S4 (2) on the transmitter for more
than 10 seconds.
2. Once the control light LED (1) starts to
flash rapidly, the transmitter has been
reset.
How to reset the receiver:
1. Press S4 (2) on the receiver for more than
10 seconds.
2. Once the control light LED starts to flash
rapidly, the receiver has been reset.