Fig. 9
Awning Wiring
1. Pull the wires from the unit through the support arm assembly. These wires may be located at the
bottom or the top of the support arm assembly.
2. Connect wiring from the unit to the switch and the awning drive head per the wiring diagram below
(Fig. 9).
NOTE: Check the switch. If the awning is running in reverse of what the switch indicates, reverse the wires.
NOTE: Solera Power Awning motors come stock with an internal 6A auto reset breaker. If this breaker trips,
it will take approximately 30 seconds to reset. LCI recommends that the awning be wired into a 15A
circuit.
NOTE: All wire to be 14 AWG or larger as necessary to provide 12V minimum at all times at the connection
to the LCI-supplied power cable.
Ground
Power
15A Circuit
per RVIA Code
(OEM Supplied)
Red
Black
Manual
Rocker
Switch
Blue
Red
Awning Motor
Battery,
Power Source
or Converter
White