107
Target frequency
during inertia
estimation
Sets the target frequency of rotation during the
inertia estimation
Default∶ 50Hz
Min.: 0
Max.: 60Hz
Rated torque during
inertia estimation
Sets the rated torque for rotation during the
inertia estimation
Default∶ 50%
Min.: 0
Max.: 100%
Motor Auto-Tuning
Setting
Enables or disables Auto-Tuning when A1-02=0 to
3
0 : Disabled
1 : Enabled
Default∶ 0
Min.: 0
Max.: 1
PM Motor
Auto-Tuning
Method Selection
0 ∶ PM Rotational Auto-Tuning
1 ∶ PM Stationary Auto-Tuning
2 ∶ PM offset angle Auto-Tuning for resolver card
3 ∶ PM offset angle Auto-Tuning for resolver card
· Perform Auto-Tuning.
· Set the correct value according to the test report
or motor nameplate.
Default∶ 0
Min.: 0
Max.: 3
Initial current for
initial position
detection
Sets the current value of the PM motor for initial
position detection
Default: 30%
Min.: 30%
Max.: 100%
0 ∶ IPM Motor
1 ∶ SPM Motor
Sets the PM motor rated output power in kW
units.
Note: 1HP (Horse Power) = 0.746kW
Default: Determined by
o2-03
Min.: 0.00 kW
Max.: 650.00 kW
Sets the PM motor rated voltage according to the
motor nameplate.
Default: 200.0 V
Min.: 0.0 V
Max.: 255.0 V <3>
Sets the PM motor rated current according to the
motor nameplate.
Default: Default: 50%
of drive rated current
Min.: 10% of drive
rated current
Max.: 200% of drive
rated current
Sets the PM motor base frequency according to
the motor nameplate.
Default: 87.5 Hz
Min.: 0.0 Hz
Max.: 400.0 Hz
Sets the number of PM motor poles according to