74
Parameter
Name
Description
Setting Range
C3-01<4>
Motor 2 Torque
Compensation Gain
Sets the gain for the motor 2 Torque
compensation
Default 0.50
Min.: 0.00
Max.: 2.50
C3-02 <4>
Torque
Compensation
Primary Delay Time
Sets the Torque compensation primary delay time.
Default 2ms
Min.: 0 ms
Max.:10000 ms
C3-03
Torque
Compensation
Primary Delay Time
2
Sets the delay time used during motor
regeneration or Speed Search.
Default 2ms
Min.: 0 ms
Max.: 10000 ms
C3-06
Torque
Compensation Time
at Start
Default 0.300
Min.: 0
Max.: 3.000
C3-07
SVVC flux control
bandwidth
Default 30
Min.: 0
Max.: 200
C3-08
SVVC low frequency
flux gain
Default 1.10
Min.: 0
Max.:1.30
C3-09
SVVC Vd boost
Default 300
Min.: 0
Max.:3000
C3-10
SVVC torque start
slope
Default 0.300
Min.: 0
Max.:3.000
C4: ASR (Automatic Speed Regulator)
C4-00
<4>
ASR Proportional
Gain 1 (P)
Sets the ASR proportional gain 1.
Default 1.00
Min.: 0.00
Max.: 300.00
C4-01
<4>
ASR Integral Time 1
(I)
Sets the ASR integral time 1.
Default 1.00
Min.: 0.000 s
Max.: 300.00 s
C4-02
<4>
ASR Proportional
Gain 2 (P)
Sets the ASR proportional gain 2.
Default 1.00
Min.: 0.00
Max.: 300.00
C4-03
<4>
ASR Integral Time 2
(I)
Sets the ASR integral time 2.
Default 1.00
Min.: 0.000 s
Max.: 300.00 s
C4-04 <9>
Speed estimator
filter gain
In the case of severe noise interference, filtering
the estimated value of the speed estimator has
Default 0.000
Min.: 0 s

Related product manuals