85
automatically during Auto-Tuning.
Min.: 0.00 A
Max.: d2-00 (excluding
d2-00)
Sets the number of motor poles. This will be set
automatically during Auto-Tuning.
Default: 4
Min.: 2
Max.: 48
Motor Line-to-Line
Resistance
Sets the line-to-line resistance. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.000 Ω
Max.:65.000 Ω
Sets the voltage drop caused by the motor
leakage inductance relative to the motor rated
frequency and current. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.00 mH
Max.:650.00 mH
Sets the motor rotor resistance. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.000 Ω
Max.:65.000 Ω
Sets the motor mutual inductance. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.0 mH
Max.:6500.0 mH
Sets the motor rated capacity. This will be set
automatically during Auto-Tuning. (1HP = 0.746
kW)
Default: o2-03
Min.: 0.00 kW
Max.: 650.00kW
Sets Motor 2 rated current. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 10% of drive
rated current
Max.: 200% of drive
rated current
Sets Motor 2 rated slip. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0 rpm
Max.: 6000 rpm
Sets Motor 2 no-load current. This will be set
automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.00 A
Max.: d2-11
Sets the number of motor 2 poles. This will be set
automatically during Auto-Tuning.
Default: 4
Min.: 2
Max.: 48
Motor 2
Line-to-Line
Resistance
Sets the motor 2 line-to-line resistance. This will
be set automatically during Auto-Tuning.
Default: o2-03, A1-06
Min.: 0.000 Ω
Max.: 65.000 Ω