154
PD-51
(N-keep)
INH
The auxiliary function
Communication
address:
0366H
0367H
Initial value
0
Control mode
ALL
Unit
N/A
Configuration range
Read only
Data size
16bit
Data format
Dec
PD-52
PLOSS
The detection of the input phase failure
Communication
address:
0368H
0369H
Initial value
1
Control mode
ALL
Unit
N/A
Configuration range
0 ~ 1 (0: Deactivation of the
input phase failure detection)
Data size
16bit
Data format
Dec
PD-53
OSPW
The condition for the overspeed warning
Communication
address:
036AH
036BH
Initial value
5000
Control mode
S
Unit
r/min
Configuration range
1 ~ 6000
Data size
16bit
Data format
Dec
PD-54
PCF
The condition for giving warnings of the
excessive error regarding the position control
Communication
address:
036CH
036DH
Initial value
480000
Control mode
P
Unit
Pulse
Configuration range
1 ~ 16000000
Data size
32bit
Data format
Dec