EasyManua.ls Logo

LIVOLTEK Hyper 5000 - Work Modes

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
3.4 Work Modes
The hybrid inverter offers four operating modes (Self-use, Self-define, backup and off-
grid) that can be configured via LIVOLTEK APP for you to determine which mode will
be best for you.
Modes
Description
Self-Use (Default)
The energy produced by the PV system will go for loads
consumption first, then charge battery, rest power
exports to grid, battery will charge or discharge
automatically based on the system condition.
Suitable for areas with the low import rate and high
electricity price.
Self-Define
Charge/discharge time can be set as customer need.
During the non-set time period, it will work in self-use
mode.
Suitable for areas with time of use tariffs which means
prices vary between peak and valley.
Backup Mode
When the grid is functional the battery is kept full
capacity and will only be allowed to discharge when grid
is unavailable
Suitable for areas with unstable grid to prolong the
autonomy in the event of grid outage. Or reducing the
frequency charging & discharging of battery to extend
battery life.
Off-grid
The critical loads will be powered by PV production and
Battery (Battery is necessary in this mode.)
Suitable for non-grid areas, and the inverter will
automatic activation this mode in the event of grid
failure.

Other manuals for LIVOLTEK Hyper 5000