64
10. Technical Data
PV Input Data
Hyper-
3000
Hyper-
3680
Hyper-
4600
Hyper-
5000
Max. PV Input Power (Wp)
4500
5520
6900
7500
Max. PV Input Voltage (V)
600
Nominal DC Input Voltage (V)
360
MPPT Voltage Range (V)
125~550
No. of MPPTs/Strings per MPPT
1 / 1
2 / 1
2 / 1
2 / 1
Max. Input Current (A)
14
14/14
14/14
14/14
Max. Short Circuit Current (A)
17.5
17.5/17.5
17.5/17.5
17.5/17.5
AC Output @ Grid
Nominal AC Power (W)
3000
3680
4600
5000
Max. Apparent Output Power
(VA)
3300
4000
4600
5500
Nominal AC Voltage (V)
220/230/240
Nominal AC Voltage Range (V)
186~290
Nominal Grid Frequency (Hz)
50/60
Max. AC Current (A)
13.0
16.0
20.0
21.7
THDi (@Rated Power) (%)
<3
Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)
EPS Output @ Off Grid
Nominal EPS Power (W)
3000
3680
4600
5000
EPS Peak Power [VA]
1.1 x Pnom, 10 sec; 1.5 x Pnom,1 sec
Nominal Output Voltage (V)
220/230
Nominal Frequency (Hz)
50/60
Nominal Output Current (A)
13.0
16.0
20.0
21.7
THDv (@Linear Load) (%)
< 3%
Back-up Switch Time (ms)
<20
Battery Data
Battery Type
Lead-acid/Lithium
Nominal Battery Voltage (V)
48
Battery Voltage Range (V)
40~60
Battery Capacity (Ah)
50~500
Max. Char/Discharge Current (A)
60
80
100
100
Communication with BMS
CAN
Efficiency
Max. Efficiency (%)
97.6
97.8