Output Voltage abnormal
(Inverter voltage is higher than
260Vac)
Check if the load power is within the EPS
power range and the AC output wires are
connected well.
Overload error. The inverter is
overload 110% and time is
up( more than Five time)
Reduce the connected load by switching off
some equipment, and wait for the recover.
Restart the inverter and contact your dealer
for technical support if the error happens
again.
Check the wires connection. Restart and
contact your dealer for technical support if the
error happens again.
BUS Voltage (AC) is too high.
Wait for inverter recovery. Contact your
dealer for technical support if the error
happens again.
The ambient temperature inside
the inverter exceeds the upper
limit.
Check the air flow of the unit, then close it
and wait for 30mins.
Contact your dealer for technical support if
the error happens again.
Battery (Lead-Acid) temperature
is not within permissible range.
Check the environment temperature. Contact
your dealer for technical support if the error
happens again.
Battery voltage is not within
permissible range.
Check the spec and quantity of battery and the
connection.
Contact your dealer for technical support if
the error happens again.
Check battery type and communication of the
BMS cable. Restart the inverter and contact
your dealer for technical support if the error
happens again.
The battery voltage is too low.
Re-charge battery and contact your dealer for
technical support if the error happens again.
Over Current occurs during
battery charging or discharging.
Restart the inverter and contact your dealer
for technical support if the error happens
again.
BUS Voltage is too high or
internal failed
Internal communication failure
(ARM&DSP).
Internal EEPROM Component
(ARM) damaged.
BMS communication failure.