3- CHAPTER 3: PROCEDURES
3-10
Home Position Proximity Switch SQ5 Adjustment
Conditions:
- Bar feed power on.
- Bar feed in STOP mode.
- Pusher at the mechanical home position.
Procedure:
Step 1: Open the main access cover.
Step 2: Make sure the carrier is in home position.
Nylon bushing is
the mechanical
home
p
osition.
Step 3: Adjust the SQ5 proximity switch position just far enough to get a strong signal from the switch (approx. 0,5
mm) and tighten down. Any slight movement forward of the carrier should deactivate the proximity sensor.
~0,5 mm
Step 4: Close the main access cover.
Step 5: Press the [STOP] key on the remote control to clear any alarm. Reference the bar feed (see "Reference
procedure").
Procedure complete.