CHAPTER 3: PROCEDURES
QUICK LOAD SERVO 65/80
3-13
TStep 7: urn the gain adjustment counter clockwise to the minimum position. A ticking noise marks the end of the
Step 8: rom the minimum position slowly turn the gain adjustment clockwise until the sensor detects the bar (a
Step 9: emove the material from the channel and close the main access cover.
ess Cover Open" alarm.
Procedure
adjusting range.
F
yellow LED will illuminate once the bar is detected). Once the sensor detects the bar continue to turn the
gain clockwise another ½ turn.
R
Step 10: Press the [STOP] key on the remote control station to clear the "Main Acc
complete.