LED
display
Address for
communication
Parameter
name
Min/Max
range
Description
Adj.
during run
Factory
defaults
Input/output group
Output item
Output to 10[V]
200V 400V
0 Output freq. Max frequency
1 Output current 150 %
2 Output voltage AC 282V AC 564V
3 Drive DC link voltage DC 400V DC 800V
Based on 10V.
Used when I54 or I55 is set to 0-4.
Cannot be set higher than F21.
0 FDT-1
1 FDT-2
2 FDT-3
3 FDT-4
4 FDT-5
5 Overload (OLt)
6 Drive Overload (IOLt)
7 Motor stall (STALL)
8 Over voltage trip (Ovt)
9 Low voltage trip (Lvt)
4.0
5.0
5.0
6.0
6.0
7.0
7.0
8.0
8.0
9.0
9.0
0 O
100 O
30.00 O
10.00 O
12
O
17
I37
I38
I39
I40
I41
I42
I43
I44
I45
I46
I47
I50
I51
I52
I53
I54
I55
A425
[Multi-Decel
time 2]
A426
[Multi-Accel
time 3]
A427
[Multi-Decel
time 3]
A428
[Multi-Accel
time 4]
A429
[Multi-Decel
time 4]
A42A
[Multi-Accel 0~ 6000
time 5] [sec]
A42B
[Multi-Decel
time 5]
A42C
[Multi-Accel
time 6]
A42D
[Multi-Decel
time 6]
A42E
[Multi-Accel
time 7]
A42F
[Multi-Decel
time 7]
A432
[Analog output
0 ~ 3
item select]
A433
[Analog output 10~200
level adjustment] [%]
A434
[Frequency
detection level]
0 ~ 400
[Frequency
[Hz]
A435 detection
bandwidth]
[Multi-function
A436 output terminal
select]
0 ~ 19
A437
[Multi-function
relay select]
iG5A
Function List
38