Chapter 5 Positioning Instructions
5 - 23
(b) Device Used
Device
Description
Data size
Example of setting
M0001
position/speed switching
instruction signal
BIT -
K4210
signal during axis X
position control
BIT -
K4201 axis X error BIT -
(c) Operation of the Program
PVT instruction is executed when there is the rising edge of M0001, which was used as the
position/speed switching instruction signal.
• It the position control is going on currently, it is switched into speed control, and the current position
is not preset but only the control method is switched to speed control.
• When using the position/speed switching instruction, make sure that the instruction is not executed
during the speed operation by using the display flag (axis X:K4210, axis Y:K4310) during position
control as the program example above.
To stop the operation after switching to speed control, use the stop instruction (STP).