Ingeniería de Servicio
Consumer Error Mode Entry
Entry into Consumer Error Mode
From an idle state only (all LEDs off), press and hold Start button for 10 seconds.
After holding Start for 10 seconds, all LEDs will turn on, signifying the user may
release the Start button.
Behaviors While In Consumer Error Mode
The Pause and Lid Locked LEDs should be constantly blinking while in CEM.
The first fault, if present, will show on the display.
Pressing Start will display the next fault code.
o Models without 7-segment display: Fault code will blink in binary – the
consumer will report which LEDs are blinking and which are not. See Binary
Display Fault Chart.
o Models with 7-segment display: Fault code will blink on the 7-segment display.
At the end of the fault list or if no faults present.
o Models without 7-segment display: All status LEDs will blink.
o Models with 7-segment display: 7-segment display will blink “-“.
Exiting Consumer Error Mode
Pressing any button (other than Start) or turning any knob will exit Consumer Error
Mode.
Consumer Error Mode will time out after 10 minutes.