Ingeniería de Servicio
- 62 -
Service Mode Tests
Knob Index / Test
number (Displayed
on SSD, 7-segment
display, if present)
(Without SSD will
be displayed in
binary format. (See
Binary Chart)
Test Name
Description of test
If tests call for numbers to be shown it will:
(Display on SSD, 7-segment display, if present)
(Without SSD will be displayed in binary format.
(See Binary Chart) Turning the cycle knob will
index to the next or prior test.
15
Agitate
Pressing Start will start the test. Agitate test will
perform child safety algorithm before it starts to
agitate. The lid must be closed to start the test. If
lid is opened the Locked LED will blink.
When started, the mode shift to agitate will occur
if required.
When mode shift is complete, the washer will
begin agitating.
The test will pause if the lid is opened after
starting. The test will resume on lid close if it was
running when opened.
The test will stop when the test is exited.
16
Clear all Fault
Codes
Pressing Start will clear all fault codes.
17
Change
Personality
Pressing Start will start the test.
Press Start button again and the next valid
personality should be displayed.
Press and hold the Start button to select the
correct personality.
18
Analog Knob
Pressing Start will start the test.
Each options knob is represented by a specific
corresponding status LED (for left options knob to
the far left status LED).
When knob position changes, the LED for the
specific knob blinks.
With each click to the right, the LED for the
specific knob blinks faster.
With each click to the left, the LED for the specific
knob blinks slower.