EasyManuals Logo

Magellan ProMark3 RTK User Manual

Magellan ProMark3 RTK
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
48
English
Stop & Go Survey Rover Setup
1. Turn on the receiver by pressing the red key.
2. Double-tap the Surveying icon.
3. If you have a ProMark3 RTK, press MENU, tap Receiver
Mode and then Post-processing.
4. Press the NAV key until you see the Satellite Status screen
(see opposite). Wait until at least 4 satellites are received.
5. When there is enough satellites received, press the LOG
key. The Survey Settings screen opens.
6. Enter the following parameters:
Site ID: A 4-character string.
Survey Mode: Stop -and-go.
Site Description: An optional 20-character narrative
description of the point.
Antenna Height: Distance from the rover antenna
mounted on the bar to the ground.
Units: Antenna height unit (meters, US feet or Int feet)
Height Type: Slant or Vertical.
Recording Interval: Time in seconds between any two
consecutive acquisitions of GPS data. Make sure the
same recording interval is used at the base and in the
rover.
Initialize: Bar.
Time on Site (sec): Occupation time on initializer bar for
the rover antenna (default: 300 seconds).
Satellite Status screen
VerticalSlant