Technical Information
1.3 Product Label
As defined in the standard EN 60974-1, the operating cycle rate includes a time period of 10 minutes. For example, if a machine specified as 250A
at %60 is to be operated at 250A, the machine can weld without interruption in the firs 6 minutes of the 10 minute period(zone 1). However, the
following 4 minutes should be kept idle for the machine cool down (zone 2).
Duty CycleX
Open Circuit VoltageU
Rated Welding CurrentI
Line Voltage and FrequencyU
Protection ClassIP21S
Rated Welding VoltageU
Input PowerS
Input CurrentI
Three Phase Transformer Rectifier
Descending Characteristic
Direct Current
Stick Electrode Welding
Mains Input-1 Phase Alternating Current
Suitable for operation at hazardous
environments