Maintenance And Service
4.2 Error Codes
FAZ ERR
Check the connections of phases (R,S,T). You can go on
welding after error message disappear.
Check the connections of phases (R,S,T) and wait for a
while for machine to cool down. You can go on welding
after error messages disappear.
Change the fuse. (1A- Delayed).
Contact to authorized technical service.
Check the phase (T) which is connected to fan.
There may be failure either in one or more of the phases
(R,S,T).
Fuse F1 may be blown out.
Fan motor may be short circuited.
There may be failure in phase (T) which is connected to
fan.
Both there is failure either in one or more of phases, and
machine is overheated.
Machine may be overheated and stopped for auto protec-
tion.