RD 500 E
EN
www.magmaweld.com
14
USER MANUAL | KULLANIM KILAVUZU
Installation
2.3 Mains Plug Connection
2.4 MMA Welding Connections
2.5 TIG Welding Connections
For your safety, never use the mans cable of the machne wthout a plug.
Since mains connection sockets may vary from factory to factory, an appropriate
plug must be installed o the builtin mains cable of the machine by qualified ele-
ctricians. Please observe that the earth cable is in yellow/green colour and labe-
led as.
After installing the electric plug, DO NOT INSERT IT INTO THE SOCKET AT THIS
STAGE.
According to the polarity of the electrode to be used, insert welding cables into
the appropriate outlet (4) and tighten them by turning clock-wise.
Connect the earth clamp tightly to the workpiece as close as possible to the welding
area.
TIG torch with a valve should be used.
Connect the TIG torch power cable to the negative outlet (4) and the earth cable
to the positive outlet (4) of the machine.
Install the Argon gas regulator onto the Argon gas cylinder.
Connect the gas hose of the torch to the gas regulator.
Fgure 2: Electrc Plug Connecton
Fgure 3: MMA Weldng Connectons
Fgure 4: TIG Weldng Connectons
Fgure 5: Connectng Gas Cylnder