Traversing length | 17.5 mm |
---|---|
Parameters | Ra, Rz, Rq, Rt, Rmax, RSm, Rmr |
Filter | Gaussian |
Cutoff length λc | 0.25 mm, 0.8 mm, 2.5 mm |
Sampling length ln | 0.25 mm, 0.8 mm, 2.5 mm |
Stylus tip radius | 2 μm |
Measuring force | 0.7 mN |
Units | μm |
Data storage | Internal memory, USB |
Interfaces | USB |
Power supply | Rechargeable battery |
Operating temperature | 40°C |
Resolution | 0.01 µm |
Standards | ISO, ASME, JIS |
General safety advice and rules for using the instrument.
Guidelines for safe electrical connection and power usage.
Procedures for identifying and rectifying safety-related faults.
Warnings and rules regarding modifications and access to components.
Describes the physical attributes and design of the instrument.
Overview of how instrument settings can be configured and protected.
Details the parameters and methods for evaluating measured profiles.
Information on data transfer and connection options like USB and MarConnect.
Mentions the availability and versatility of optional accessories.
Specifies the environmental conditions for storage and operation.
Steps for powering on, basic settings, and measurement conditions.
Instructions for removing the protective shipping clamp before use.
Detailed instructions for calibrating the probe using the standard.
Additional steps for configuring instrument parameters.
Steps to initiate and perform a measurement.
Procedure for safely powering down the instrument.
Information on how to charge the instrument's internal battery.
Instructions for setting up the instrument for mobile use.
Instructions for integrating the instrument with measuring stands.
Steps to detach the drive unit from the main instrument.
Guide to detaching the vee-block holder for component changes.
Steps to reattach the vee-block holder to the drive unit.
Procedure for reattaching the drive unit to the instrument.
Settings for measurement path, sampling lengths, and filters.
Configuration of Lc filter, drive, speed, and probe type.
Settings for probe calibration, parameter evaluation, and tolerances.
Settings for data export, security, display, and power management.
Settings for function keys, basic options, remote control, and system info.
Customizing measurement records with logos and text.
Guide for transferring data using MarCom software.
Procedures for cleaning the instrument and probe.
Recommendations for storing the instrument and accessories.
Guidelines for safely transporting and shipping the instrument.
Procedure to verify the calibration standard's Rz value.
Instructions for replacing the internal rechargeable battery.
Steps to update the instrument's software.
List of consumable and replacement parts.