Digimar 817 CLM Quick Height
Height Measuring Instrument
Operating instructions
3759019
Version 1.02-30 en
Mahr GmbH Esslingen
D-73702 Esslingen • Postfach 10 02 54
Telefon (07 11) 9 31 26 00 • Fax (07 11) 9 31 27 25
e-mail: mahr.es@mahr.de
http: //www.mahr.de

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mahr Digimar 817 CLM and is the answer not in the manual?

Mahr Digimar 817 CLM Specifications

General IconGeneral
DisplayLCD
Repeatability0.001 mm
Measuring speedMax. 1.5 m/s
Protection classIP40
Accuracy± 0.002 mm
Power SupplyBattery
Operating temperature0°C to 40°C
Data interfaceRS-232
Storage Temperature-10 to +60 °C
Resolution0.001 mm

Summary

Safety Instructions

Delivery and Setting Up

Description and Explanation of the Height Measuring Instrument

Height Measuring Instrument Components

Detailed explanation of the various parts of the height measuring instrument with numbered labels.

Keypad Layout and Functions

Explanation of the different key groups and their functions on the instrument's keypad.

Display Elements Explained

Describes the various elements displayed on the instrument's screen and their meanings.

Commissioning and First Steps

Configuring Basic Settings

Guide to configuring essential initial settings like language, units, and resolution.

Setting the Reference Point

Procedure for establishing the instrument's zero point on the base plate.

Calibrating the Measuring Probe

Step-by-step guide on how to calibrate the measuring probe for accurate readings.

Brief Guide to Measurement Methods

Measuring a Bore

Step-by-step instructions for measuring the diameter and center of a bore.

Measuring a Shaft

Step-by-step instructions for measuring the diameter and center of a shaft.

Measurement Procedures in Quick Mode

Measurement Procedures Using Speed Keys

Operating and Measuring in Detail

Standard Probe Calibration

Detailed procedure for standard calibration of the measuring probe.

Calibrating a Probe with a Setting Standard

Step-by-step instructions for calibrating the probe with a setting standard.

Calibrating a Twin Probe

Procedure to calibrate a twin probe and its associated functions.

Calibrating a Probe with a Ledge

Detailed steps for calibrating a probe against a ledge.

Zero Points Management

Setting the Zero Point on the Base Plate

Instructions for setting the basic zero point on the instrument's base plate.

Setting Workpiece Zero Point 01

Procedure to set the first workpiece zero point (01).

Setting Workpiece Zero Point 02

Procedure to set the second workpiece zero point (02).

Setting Workpiece Zero Point 03

Procedure to set the third workpiece zero point (03).

Entering a PRESET Value

Guide to entering a preset value, which acts as an offset zero point.

Expanding the Measuring Range

Basic Measuring Functions

Dynamic Measuring Functions

MAX-MIN Function for Extreme Values

How to use the MAX-MIN function to find extreme values during measurement.

Measuring Perpendicularity Error

Measuring in 2D Mode

Entering Tilting Angle for Arithmetic Alignment

Procedure for entering a tilting angle for arithmetic workpiece alignment in 2D mode.

Index Circle and Best Fit Circle Calculation

Procedure for calculating index circles or best fit circles using multiple points.

Coordinate Transformation for Workpiece Alignment

How to align the workpiece arithmetically in 2D mode using coordinate transformation.

Measuring Tapers and Calculating Angles

Deleting, Saving, and Printing Measured Values

Deleting Measured Values

Instructions for deleting measured values, either the last or all.

Saving Measured Values to a PC

Steps to connect and save measured data to a PC via USB.

Printing Measured Values / Results

Basic Settings

Data and Printer Configuration

Printer and Interface Settings

Advanced Settings

Temperature Compensation Setup

Setting up temperature compensation for accurate measurements.

Probe Calibration Parameters

Using Correction Tables for Accuracy

Delete Menu and Clear Function

Memory Data Deletion Options

Deleting All Instrument Data

How to delete all data from the instrument's memory.

Customer Calibration Procedures

Z-Axis Correction Factors

How to calibrate correction factors for the Z-axis, including data deletion.

Creating a Measuring Program

Adjusting Nominal Values in Programs

Starting Programs and Applying Correction Tables

Perpendicularity Error Correction

Self-Help, Maintenance, and Care

Troubleshooting Common Issues

Common problems, their reasons, and solutions for the instrument.

Instrument Maintenance and Care

Available Accessories

Technical Data Specifications