Home
Mahr
Measuring Instruments
Digimar 816 CL
Mahr Digimar 816 CL User Manual
62 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
Mahr GmbH
St
andort Esslingen
R
eutlinger Str
. 48, 73
728 Esslingen
Tel
. +49 7
1
1 93
1
2-600, Fax +49 7
1
1 93
1
2-756
mahr
.es@mahr
.de, www
.mahr
.com
Digimar 8
1
6 C
L
Height Measuring Instrument
Oper
ating instructions
3759587-en
V
ersion 1.8
1014
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Delivery and Setting up
5
Scope of Supply
5
Unpacking
6
Description and Explanation of the Height Measuring Instrument
13
Height Measuring Instrument
13
Keypad
14
Display
14
Description of the Symbols
15
1.3.4.1 Keypad Symbols
15
Function Key Symbols
15
Symbols - Display
17
2 Commissioning / First Steps
18
Switching on
18
Calibrating a Probe
19
Moving / Positioning the Height Measuring Instrument
19
First Measurement
20
Contacting a Surface from above
20
2.4.2 Measuring a Bore
20
Switching off
21
3 Operation and Measurement
22
Standard Calibration / Calibrate a Probe
22
Calibrating a Probe Using a Groove
22
Calibrating a Probe Using a Ledge
23
Calibrate with a Taper Probe
24
Deviations Caused by Calibration
24
Zero Points
25
Set the Zero Point on the Base Plate
25
Entering a PRESET Value
25
Expanding the Measuring Range
26
Basic Measuring Functions
27
Contacting from above
27
Contacting from below
27
Measuring a Groove
27
Measuring a Bore
28
Function Keys
29
Calculating a Distance
29
Calculating Symmetry
29
Relative / Absolute Zero Point
30
FTC-Function Key
30
MIN/MAX-Function
31
Measuring a Ledge
32
Measuring a Shaft
32
Contacting a Bore from below
33
Contacting a Bore from above
33
Center of a Bore / Display the Position
33
Contacting a Shaft from below
34
Contacting a Shaft from above
34
4 Delete, Save and Print Measured Values
35
Delete
35
Delete All Measurements
35
Delete an Individual Measurement
35
Delete an Entry
36
Return
36
Print Measured Values
36
Print with a MSP 2 Printer
36
Send Measured Values
36
5 Menu - Basic Settings
37
Data Transmission
37
Basic Settings / Symbols
37
Interfaces
38
Send a Series of Measured Data
39
Select Measured Data
40
Create a Record Head Data
40
Resolution
41
Acoustic Signal
42
Contacting Speed
42
Standstill-Time
42
Contacting Parameter (Probe Lift)
43
Time / Date
43
Switching the Unit of Measurement MM / Inch
43
Display
44
Factory Settings
44
Service / Customer Service (Reserved Only for Mahr)
44
Select a List of Measurements
45
Software Update
45
6 Measuring Program
47
Create and Save a Measuring Program
47
Start a Measuring Program
48
7 Additional Functions
49
Data Transmission with Marcom
49
Temperature Compensation
50
7.2.1 Display the Temperature
50
Active Temperature Compensation
50
8 Self-Help, Maintenance and Care
52
Maintenance and Care
52
Cleaning the Height Measuring Instrument
52
8.1.2 Charging the Batteries
52
Exchanging the Batteries
53
Troubleshooting
54
9 Accessories
55
10 Technical Data
59
11 Alphabetical Index
60
12 Declaration of Conformity
62
Need help?
Do you have a question about the Mahr Digimar 816 CL and is the answer not in the manual?
Ask a question
Mahr Digimar 816 CL Specifications
General
Display Type
LCD
Repeatability
0.00005 inch / 0.001 mm
Measuring force
≤ 1.5 N
Data output
RS232
Operating Temperature
10 - 40 °C
Related product manuals
Mahr Digimar 817 CLM
152 pages
Mahr Digimar 817 CLT
38 pages
Mahr Digimar M 814 G
66 pages
Mahr Pocket Surf IV
27 pages
Mahr 25 ES
14 pages
Mahr Millimar S 1840
101 pages
Mahr Millimar C 1202
88 pages
Mahr Maxum III
56 pages
Mahr umaxum II
72 pages
Mahr MarSurf RD 18
72 pages