Mahr GmbH • Digimar 816 CL
EN
Description / Sequence Symbols / Pictures
5.5 Standstill-time
When making contact with the work piece, the probe bounces for a
short time and the measuring value oscillates accordingly. The
measuring value can only be accepted when it is stable.
Thus a suitable time constant - the die-down time - needs to be
selected. The standard die-down time is 1 second. The operator can
decide whether another die-down time (0.5; 1; 2; 4 s) is required.
Standard setting: Standstill-time 1 s
Press the function key „Standstill-time“
Select the standstill-time
Confirm by pressing the „Accept“ key
5.3 Acoustic signal tone
The signal tone can be quiet / loud / off
Standard setting: Loud
Press the function key „Acoustic signal“
Select the acoustic signal
Tone quiet
Tone loud
Tone off
Confirm by pressing the „Accept“ key
5.4 Contacting speed
Standard setting: Speed 8 mm/s
Press the function key „Contacting speed“
Select the contacting speed mm / second
Confirm by pressing the „Accept“ key
MENU
9
MENU
9
MENU
9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mahr Digimar 816 CL and is the answer not in the manual?

Mahr Digimar 816 CL Specifications

General IconGeneral
BrandMahr
ModelDigimar 816 CL
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals