E 300 Operator Interface
M&R Printing Equipment, Inc. - Glen Ellyn, Illinois
44
Lastly, in the upper right corner of the screen, the
current time of day is displayed. (See Figure 4 above)
The “Shift Counter” displays the production shift.
The “Shift Counter” may be reset using the arrow
keys, the numerical keys and the “ENTER” key as
follows. First, press the “RIGHT ARROW” key. The
numerical display for “Shift Counter” will start to
flash, confirming its selection. To reset the “Shift
Counter”, press the “0” key on the numerical key-
pad, then press the “ENTER” key. The display for
“Shift Counter” is now reset to “0”.
The “Job Counter” displays the current number of
index cycles for a given print job. The “Job
Counter” may be reset in the same manner as
described above for “Shift Counter”.
The “Total Counter” displays the total number of
press cycles beginning from the initial date of instal-
lation of the equipment in your production facility.
The numerical value for the “Total Counter” cannot
be changed or adjusted in any way. It merely serves
as a reference for the systems operational history.
TIMERS -
The “TIMERS” menu contains four sub-menu items
which are, “Index”, “Flash”, Quartz” and
“Preheat”. You may access each of these sub-menu
areas by using the “ARROW DOWN” key to scroll
down through the L.C.D. display. (See Figure 5 on
the next page)
Index Dwell Time is used to control the dwell time
when operating the system in the automatic mode.
Dwell time is defined as the time interval during auto-
matic operation in which the system operator may
load and/or unload garments. The dwell time starts
at the completion of the index cycle. The dwell time
is adjustable from a minimum of “0” seconds, to a
maximum of “20” seconds and may be adjusted to
suit the system operators requirements as follows.
Press the “ARROW RIGHT” key. The numerical
value for dwell time to the right of “Index” will start
to flash, confirming its selection. Now, simply press
the numerical keys to select the desired amount of
Figure 4