E 300 Operator Interface
M&R Printing Equipment, Inc. - Glen Ellyn, Illinois
52
The adjustment has a range of between “0.01” sec-
ond and “2” seconds delay time. To adjust the
“Front Delay” time, enter the desired time interval
using the numerical keys, then press the “ENTER”
key one time. Your selection is now saved in the
Press the “RIGHT ARROW” key one time to access
the “Front Duration” dwell time. This sub-menu
item permits the adjustment of the time duration in
which the front air valve which operates the front
spray gun is activated. This adjustment, like the
“Front Delay” adjustment described above, permits
the system Operator to precisely set the two front
spray guns to synchronize with the current index
speed. The adjustment has a range of “0.00” sec-
onds to “2” seconds. Use the numerical keys to
enter the desired time value, then press the
“ENTER” key one time. Your selection is now saved
in the PLC memory. (See Figure 12 above)
The next sub-menu item is “Rear Delay”. This sub-
menu item permits the system Operator to program
a start delay time for the one rear air valve which
operates the rear spray gun. As with “Front Delay”
described previously, this adjustment is provided to
precisely set the spray gun trigger cycle to the speed
of the indexer when operating the press in the auto-
matic mode. The adjustment has a range of “0.01”
second to “2” seconds delay time.
To adjust the “Rear Delay” time, press the “RIGHT
ARROW” key so that the flashing cursor is located
under the current indication. Now using the numeri-
cal keys, enter the desired delay time, then press the
“ENTER” key. Your selection is now saved in the
PLC memory. (See Figure 12 above)
The next sub-menu item is “Rear Duration”. This
sub-menu item permits the adjustment of the time
duration in which the rear air valve which operates
the rear spray gun is activated. This adjustment, like
the “Rear Delay” adjustment described previously,
permits the system Operator to precisely set the one
rear spray gun to synchronize with the current index
speed.
Figure 12
GLUE APPLICATOR
Spray 1 Revltn Only: Off
Spray Every: 0 Revolution
Front Delay: 0.01 [s] Duration: 0.00 [s]
Rear Delay: 0.01 [s] Duration: 0.00 [s]
Revolution #: 0 Pallet #: 0
TIMERS
nozzle TESTS MPR Pg Dwn Pg Up