E 300 Operator Interface
M&R Printing Equipment, Inc. - Glen Ellyn, Illinois
53
The adjustment has a range of “0.00” second to “2”
seconds. To adjust the “Rear Duration” time, press
the “RIGHT ARROW” key so that the flashing cursor
is located under the current indication. Now using
the numerical keys, enter the desired delay time,
then press the “ENTER” key. Your selection is now
saved in the PLC memory.
The next sub-menu item is “Revolution #”. This
menu item is used to provide the system Operator
with a visual indication of the current number of rev-
olutions remaining before the M&R Annamister auto-
matically applies adhesive to the printing pallets as
determined by the Operator’s selection in the “Spray
Every…” sub-menu item as described previously.
The indication displayed shows a countdown of
remaining revolutions. For example, if the selection
for “Spray Every…” was “20”. Then the indication
will begin at “20” and countdown to “0” at which
time the M&R Annamister system will begin applying
adhesive to the printing pallets. (See Figure 13
above)
The next sub-menu item is “Pallet #”. This menu
item is provided as an indication of how many pallets
remain until the end of the current revolution. (See
Figure 13 above above)
You will note that across the bottom of the display
screen is a dark bar with “TIMERS”, “NOZZLE”,
“TESTS”, “MPR”, “Pg Dwn” and “Pg Up”. Except
for “NOZZLE” and “Pg Dwn” and “Pg Up” these
functions work as explained previously. “NOZZLE”
is used to manually activate the M&R Annamister
spray guns. Simply press the button below “NOZ-
ZLE” which normally would be “OPTIONS”, and the
spray guns will dispense adhesive for as long as you
hold the button “IN”. Additionally, the green L.E.D.
above the “GLUE” indicator at the top of the control
panel will also illuminate. Press the buttons below
“Pg Dwn” or “Pg Up” to scroll down through the
menu item.
Figure 13
GLUE APPLICATOR
Spray 1 Revltn Only: Off
Spray Every: 0 Revolution
Front Delay: 0.01 [s] Duration: 0.00 [s]
Rear Delay: 0.01 [s] Duration: 0.00 [s]
Revolution #: 0 Pallet #: 0
TIMERS
nozzle TESTS MPR Pg Dwn Pg Up