PREVENTIVE MAINTENANCE PROCEDURE
CHALLENGER Series II Bulletin No. PH4
Maintenance Point
Frequency Interval
Procedure Information
Clean away old grease, dirt or lint and apply a fresh coat of 10 wt. non-detergent oil (M&R Part No. 7017000) to the
print carriage stroke cylinder (Tol-O-Matic band cylinder) on each print station.
Weekly
Tools required:1 - M&R Part No. 7017000 10 Wt. non-
detergent oil
1 - Cloth wiper (shop towel)
1. Disconnect, lock out and tag the electrical and pneumatic
power from the equipment.
2. Disconnect the compressed air supply from the equip-
ment by closing the manual shut-off valve. The manual shut-
off valve is closed when the handle is positioned across the
air supply pipe/hose. (See illustration at right)
3. Bleed off any compressed air which may remain in the
system by opening the small pet-cock valve (turn handle
counterclockwise to open valve) at the bottom of the mois-
ture trap assembly. Allow any compressed air to completely
evacuate the system before closing (turn handle clockwise to
close) the pet-cock valve.